• Quote Request
  • 1300 820 752
  • sales@teralba.com
Search
Teralba Logo 50 Years
  • Products

    HYGIENIC RANGE

    • TUBE IN TUBE
    • SHELL & TUBE
    • TRI TUBE
    • COILFLO
    • ACCU-THERM PLATE
    • THERMPRO PACKAGED
    • VINPRO
    • DOUBLE TUBE SHEET

    INDUSTRIAL RANGE

    • Shell & Tube
    • Tube in Tube
    • Plate Heat
    • Coilflo
    • Temp-Plate Immersion
    • Thermpro Packaged
  • Applications

    HYGIENIC INDUSTRIES

    • Food & Dairy
    • WINE & Beverage
    • PHARMACEUTICAL

    INDUSTRIAL INDUSTRIES

    • WASTE WATER
    • ENERGY RECOVERY
    • MINING
    • CHEMICAL
    • OIL & GAS
  • Service & Maintenance
    • Heat Exchanger Assessments
    • Installation & Commissioning
    • Maintenance
    • Spare Parts
  • CASE STUDIES
  • Resources
    • News/ Articles
    • Product Manuals
    • Downloads
    • Videos
  • About Us
    • Company Vision
    • Company Profile
    • Careers at Teralba
    • Quality Standards
    • Environmental Awareness

TWO PLATES ARE BETTER THAN ONE

  • Anastacia B & StephenG
  • September 11, 2015
Table of Contents

Ever heard the expression “two heads are better than one”? How about “two plates are better than one”? No – not two plates of dessert, greedy. I’m talking about Accu-Therm Double Wall Plate Heat Exchangers.

Teralba Industries recently completed a special order for one of our long-standing customers Equilibrium Air Conditioning.  The order was special for a few reasons – it was for a Sydney hospital, it was a special design, and it was for a special application.

So what’s so special about a Double Wall Plate Heat Exchanger? Double Wall Plate Heat Exchangers are a little bit different from normal Plate Heat Exchangers – they account for the very small chance that the plates could leak, allowing liquid from one side of the plate to contaminate the other.

As the name suggests, it has a second plate welded to each normal plate at the ports. This leaves a tiny gap between the welded plates, which is where any potential leaked fluid would flow – staying isolated, alerting us that there is a leak and allowing us to change the leaking plate. In a Single Wall Plate Heat Exchanger, this leak could very well go unnoticed and cause cross contamination.

Double Walled Plate Heat Exchanger

One such special application is the creation of potable water or improved drinking water. This particular Sydney hospital creates its own potable water, and our special Heat Exchanger has an important role to play in getting it ready for human consumption!

The water is treated several ways to remove any nasties including bringing the water to boiling temperature. Once it has been treated and all the gross bits have been removed, it’s time to chill the water. The water is then pre-cooled by being put through one side our trusty Double Wall Heat Exchanger, while cooling tower water is put through the other.

This tower water is the reason that the special design comes into play. Tower water is exposed to the elements and can be full of dirt, sticks, bugs and all sorts of other lovely things! If one of the plates was to fail, the tower water would contaminate the newly clean drinking water and it would be all over.

What? Why don’t we cut out the middle man and put the water directly into the chiller? You want to do away with our special Heat Exchanger?!  Well let me tell you why. To put the near boiling water straight into a chiller, you would need an extremely large, extremely powerful chiller – more affectionately known as a power sucker! By pre-cooling the water, the chiller can be small enough to fit into the designated space at the hospital. Pre-cooling the water is also much more cost effective because it doesn’t cost anything to have to cooling tower water stored and on hand when it is needed.

Need a Plate Heat Exchanger selected for your special application? Contact our friendly team now!

Subscribe To Our Newsletter

Get updates and learn from the best

STAY UPDATED

Get the latest product innovations and cutting-edge tech updates delivered straight to your inbox!

Newsletter Subscription From

This field is for validation purposes and should be left unchanged.

  • Quick Links
  • Home
  • About Us
  • Applications
  • Learning Hub
  • Articles
  • Contact
  • Terms of Sale
  • Privacy Policy
  • Products
  • Heat Exchangers
  • Processing Systems
  • Stainless Steel Fabrication
  • Dimple Technology
  • Service & Support
  • Installation & Commissioning
  • Maintenance
  • Heat Exchanger Assessments
  • Spare Parts
  • Product Manuals
  • Downloads

Contact Us

  • Location: 15-19 Kialba Road, Campbelltown NSW 2560
  • Phone: +61 (02) 4629 3000
  • Fax: +61 (02) 4625 4591
  • Email: sales@teralba.com

© Teralba Industries .
Website by Nelson O’Neill Digital Marketing Agency

Facebook-f Linkedin-in Youtube
Teralba Industries Teralba Industries
Welcome back
Sign In
Sign in to access your downloads, manage your account, and continue where you left off.
Login Account
Enter your credentials to access your account
Forgot Password?
Don't have an account? Register Now